ACTentry A10 Operating and Installation Instructions
0 Relay time 5s
1 Door 2 / Output 2 time 5s
2 Output 3 time 5s
3 Door Ajar time 30s
4 Guest Buzzer time 2s
Option Function Default Operation
30 Door Chime Off When set, whenever the door contact is opened, the built-in buzzer makes a
chime sound and the buzzer output activates for 2 seconds.
31 Silent Operation Off When set, the keypad operates silently, that is no audible tones (key-presses
or confirm tones) are produced from the built-in buzzer function (function 0).
32 Permanent On When set (default), the keypad illumination is always on. This option will
Backlighting override option 42 (Auto backlighting)
33 Locksaver Off When set, andwhen the relayis active (following a valid code or buttonrelease),
(Anti Tailgating) the relay timer is truncated to 2 seconds when the door contact opens. This
ensures that irrespective of programmed relay time, the door will be locked
as soon as it closes, and any person following will have to enter a code.
34 Alarm Off When set, the keypadmay be usedasa remote keypad for an alarmsystem. Thered
Keypad and greenindicators arecontrolled bythe door contact and therelease button inputs
Operation inputs respectively, and the built in buzzer is controlled by the interlock input.
35 Interlock Off When set, two or more keypads may be interlocked so that only one controlled
door may be open at any one time. The interlock output is active whenever the
relay is active or when the door contact is open. When the interlock input is
active the release button and all codes are inactive, and the red indicator flashes.
The interlock outputs and inputs of any number of keypads may be combined
on a single wire.
36 Six Digit Codes Off When set, all user codes, and the programming code, are six digits long. The
Codes default user one code becomes 123456 and the default programmer code
becomes 999999.
37 Twin Codes Off When set, two different codes must be entered within 15 seconds in order to
open the door. The outputs activated are those which have been programmed
for the first code to be entered.
Timer No. Function Default
Timers may be set to any duration between 2 seconds and 4 minutes.
Setting Configuration:
(From programming mode)
Enter 30-37 or 40-47 (Option number)
0-1 (1= Set, 0 = Unset)
7