ACTsmart2 1070 / 1080 / 1090 Reader / Controller
Operating Voltage 12 - 24 Volt AC or DC
Current Consumption 60 / 100 mA
Output Current Sink 100 mA
Operating Temperature -25 to +60ºC
Door Open Time 0 – 255 seconds
Programmable Inputs 1
Programmable Inputs/Outputs 2
Relay Contact Rating 5 amp / 30 Volts
Size (H x W x D, mm) 100 x 110 x 35
Weight 173 grams
Mounting surface / flush mount options
Installation indoor / outdoor (IP67)
Construction rugged polycarbonate housing,
stainless steel keys, potted
electronics in the 1080 / 1090
ACTsmart2 per network (max) 8
Length of Network (max) 1.4 km
ACT 433RX Receiver
Operating Frequency 433.92 MHz
Modulation FSK
Supply Voltage 5 Volts or 12 Volts
Current Consumption 60mA
Range in free space (max) up to 50 metres
Operating Temperature -20 to +70°C
Dimensions (HxWxDmm) 109 x 100 x 24
Weight 106 gms
ACT 433TX & TXprox Transmitters
Operating Frequency 433.92 MHz
Modulation FSK
Supply Voltage 6 Volts
Current Consumption 4mA
Range in free space (max) up to 50 metres
Operating Temperature -20 to +70°C
Dimensions (H x W x D, mm) 71.5 x 42.5 x 16
Weight 20 grams
E.R.P 5uW
Batteries Two CR2032
Battery Life up t o 2 years
Transmission period 2.3 seconds
Transmission duration 7 m seconds
Product Specificatons