When Performance Counts
48
From To Network Type Cable Type** Comments
ACTpro Controller ACTpro Door stations
(ACTpro 100 / 200)
RS485 Screen twisted pair(STP) equivalent to Belden 9501 or shielded Cat5. Max distance 1.4 km. 14 additional doors
ACTpro Controllers / Door Stations ACTpro-X readers ACT protocol 8 core Screen Max distance 100m if powered from 12V source
Master ACTpro Controller (Hub mode) ACTpro Controller RS485 Screen twisted pair(STP) equivalent to Belden 9501 or shielded Cat5. Maxi distance 1.4 km (31 additional controllers)
PC* ACTpro Controller TCP/IP Cat5 Max distance of 100m. If using an ACTpro 2000 an ACT LAN is required
PC* ACTpro Controller RS232 Screen twisted pair (STP) Max distance of 20m. If Hub mode is required with the ACTpro 2000 then connect via the network .
Needs Single Channel Interface (ACT Net IF-1)
PC* ACTpro Controller RS232 to RS485 Screen twisted pair(STP) equivalent to Belden 9501 or shielded Cat5 Max distance 20m for RS232 and 1.4km for RS485. Needs Single Channel Interface (ACT Net IF-1)
*The ACTpro 3000 controllers can either be connected to the computer via TCP/IP or Serial
Cabling Chart
ACTpro 3000 Door Controller with
up to 16 doors, connected via a
serial port (RS232) to a PC running
the ACTWin software
** Note: If using UTP (Unshielded Twisted Pair) such as Cat 5 please ensure that the cable is not located near sources of electrical noise.