When Performance Counts
63
Installation Notes
ACTentry V-IP Door Entry Panel
Mount on a wall near the entrance point 
and in a sheltered location
Sink or mount onto the mounting surface 
at a height which puts the camera lens at
eye level
ACTentry V-IP Control Unit
Mount in secure place with an Ethernet 
network connection point in close
proximity, no greater than 100 metres
from the door entry panel.
A 12 Volt DC , 1 Amp power supply is to 
be used to power the unit and the door
entry panel audio and video module’s.
The door entry panel and the unit are 
to be wired together using one CAT 5
twisted pair Cable. Audio and mic must
be on one pair and video and 0V on
another pair.
The VIP can be configured with a static IP 
address for the LAN or get it’s IP address
from the DHCP server.
ACTentry V-IP Software
PC should be connected to a TCP/IP 
network.
Install on any PC where the user is 
expected to answer calls and allow
access to the building
Use the CD provided to install the 
software.
ACT PC Handset
Mount the PC Handset in a location that 
is easily accessible and unobstructive for
the user.
ACTentry A10 Door Entry Panel
The unit should be mounted on a wall 
near the entrance point, and in a sheltered
location
Remember to place the supplied varistor 
across the terminals of the door strike coil
to protect the relay contacts
Never use the on-board relay to switch 
AC mains voltage. An external relay,
electrically isolated from the ACTentry A10
should be used for this purpose.
Remember to change the programming 
code
ACTentry A10 Door Intercom
Handset
The ACTentry Door Intercom Handset 
(handset) operates from 12 Volt AC or DC
The handset is designed to be wall 
mounted in a convenient indoor location
For optimum speech clarity, it is strongly 
recommended that this system should
be installed using twisted-pair telephone
cable.
Up to a maximum of 4 handsets may be 
installed per Door Entry Panel
The maximum distance between the Door 
Entry Panel and the last handset is 100
metres.
ACTentry V-IP Audio Video over TCP / IP Door Entry
ACTentry A10 Audio Door Entry