Installation Notes
Readers
Controller
Smart Lock
ACTsmart2 1070 (RFID Prox only)
ACTsmart2 1080 (Pin and RFID prox)
ACTsmart2 1090 (PIN only)
May be installed in exposed outdoor
conditions (IP67)
If the electronic outputs and inputs are
to be used, or the master slave feature is
required, ensure a DC supply to all units
As there are up to 1,000 users available
on the ACTsmart2 devices, the system
administrator should keep good records
to enable efficient addition and deletion
of users
When using the master slave option
ensure that there is at least one
ACTsmart2 1080 device when proximity
is being used.
ACTsmart2 Controller
The ACTsmart2 controller is used when
connecting the the ACTsmart readers/
controller to a PC running the ACTSmart
software.
The ACTsmart2 controller will support a
maximum of 8 access points.
The maximum network cabling distance
from the ACTsmart controller to the last
ACTsmart readers/controller is 1.4 km of
twisted screen pair or category 5
The ACTsmart2 controller can only be
connect to the PC via a serial (RS232)
cable.
ACTsmart2 Lock
Maximum distance of Data Line from
ACTSmart2 Lock to ACTSmart2 device:
30 metres
ACT recommends installing the
ACTSmart2 Lock inside the power
supply unit.