When Performance Counts
51
ACTpro-X Readers
May be installed in exposed outdoor
conditions (IP67)
May be up to 100m when powered from
+12V DC
May be a maximum of 30m from the
controller when powered from +5V DC
Use 8 core screened cable
Note: The +5 Volt reader supply on ACT
controllers is normally rated at 100mA.
Typically this is sufficient to power 2 ACTpro
Readers.
Readers
ACTpro 2000
The ACTpro 2000 requires a 12 Volt DC
supply
The controller may not be installed
outdoors unless it is in a sealed and
heated cabinet
The ACTpro 2000 is expanded from 2 to
16 access points via “single door ACTpro
100” or the “two Door ACTpro 200”
Expanders
The ACTpro 2000 is compatible with
ACTWin Pro and ACTWin Lite software
packages.
The ACTpro 2000 controller will operate
standalone or can be connected to a PC
via the onboard
• Serialport(RS232)
• RS485.(ACTsupplyanACTIF1which
converts RS485 to RS232)
The ACTpro 2000 Controller may be
networked via an RS485 interface to
expand the system up to a maximum of
32 controllers (512 doors).
ACTpro 3000
The ACTpro 3000 requires a 12 Volt DC
supply
The controller may not be installed
outdoors unless it is in a sealed and
heated cabinet
The ACTpro 3000 is expanded from 2 to
16 access points via “single door ACTpro
100” or the “two Door ACTpro 200”
Expanders
The ACTpro 3000 is compatible with
ACTWin Pro and ACTWin Lite software
packages.
The ACTpro 3000 controller will operate
standalone or can be connected to a PC
via the onboard
• RJ45 TCP/IP port
• Serial port (RS232)
• RS485. (ACT supply an ACT IF1 which
converts RS485 to RS232)
The ACTpro 3000 Controller may be
networked via an RS485 interface to
expand the system up to a maximum of
32 controllers (512 doors).
Controllers
Installation Notes